Description
Thermostat Ordinary Area (25°F - 325°F // -4°C - 163°C) - Corrosive pipe sensing applications for freeze protection and process maintenance piping.
Stainless Steel capillary composition
Internal Adjustment
NEMA 4X, IP66 epoxy coated metal enclosure
Ambient compensated
Single Pole Double Throw Switch
Maximum Bulb Temperature: 420°F , 215°C
Capillary Length: 10 ft.
Switch: 22A/480V, SPDT
Approvals/Classifications:
UL for Ordinary Locations
CSA for Ordinary Locations
CE for Ordinary Locations